Products
Flam Burner with production above quality standards
today is one of the few manufacturers in Turkey burner.
Flam Burner with production above quality standards
today is one of the few manufacturers in Turkey burner.
PRODUCTS | Capacity min. kW | Capacity max. kW | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SC 3.2 GLM Gas /Light oil Modulation Monobloc Burner
SC 3.2 GLM Gas /Light oil Modulation Monobloc Burner
1. The following fuels can be used:
Natural gas PCI 6,99…11,39 kWh/Nm3. LPG, 25,89 kWh/Nm3 Light oil, viscosity 6 mm2 / s at 20 ° C, PCI11,86 kWh / kg 2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc. 3. The flame can be adjusted according to the combustion chamber. 4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation. 5. The 1/ 10 regulation of the electronic modulation power, is really advantageous compared to our rivals. 6. Flame monitoring is easy and reliable thanks to the UV sensor. 7. A customized type of sensor is used for sequentially installment of several generators. 8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system. 9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power. 10. It has the characteristics of proper functioning in different combustion chambers. 11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood. 12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions. 13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system. 14. Ease of installation of the gas train to the burner. 15. Standard protection of IP 54 mechanical parts. 16. IP 65 protection on demand. 17. Internal or external optional circulation of combustion gases in order to reduce NOx emissions. 18. It includes all the cables and power supply of the burner management system. 19. Includes impermeability control. 20. Compliance with the following directives: 89/336(2004/108)EEC 73/23/EEC 98/37/EEC EN 676 21. Sound insulated ventilation system |
130 | 650 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SC 5.1 GLM Gas /Light oil Modulation Monobloc Burner
SC 5.1 GLM Gas /Light oil Modulation Monobloc Burner
1. The following fuels can be used:
Natural gas PCI 6,99…11,39 kWh/Nm3. LPG, 25,89 kWh/Nm3 Light oil, viscosity 6 mm2 / s at 20 ° C, PCI11,86 kWh / kg 2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc. 3. The flame can be adjusted according to the combustion chamber. 4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation. 5. The 1/ 10 regulation of the electronic modulation power, is really advantageous compared to our rivals. 6. Flame monitoring is easy and reliable thanks to the UV sensor. 7. A customized type of sensor is used for sequentially installment of several generators. 8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system. 9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power. 10. It has the characteristics of proper functioning in different combustion chambers. 11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood. 12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions. 13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system. 14. Ease of installation of the gas train to the burner. 15. Standard protection of IP 54 mechanical parts. 16. IP 65 protection on demand. 17. Internal or external optional circulation of combustion gases in order to reduce NOx emissions. 18. It includes all the cables and power supply of the burner management system. 19. Includes impermeability control. 20. Compliance with the following directives: 89/336(2004/108)EEC 73/23/EEC 98/37/EEC EN 676 21. Sound insulated ventilation system |
200 | 750 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SC 5.2 GLM Gas /Light oil Modulation Monobloc Burner
SC 5.2 GLM Gas /Light oil Modulation Monobloc Burner
1. The following fuels can be used:
Natural gas PCI 6,99…11,39 kWh/Nm3. LPG, 25,89 kWh/Nm3 Light oil, viscosity 6 mm2 / s at 20 ° C, PCI11,86 kWh / kg 2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc. 3. The flame can be adjusted according to the combustion chamber. 4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation. 5. The 1/ 10 regulation of the electronic modulation power, is really advantageous compared to our rivals. 6. Flame monitoring is easy and reliable thanks to the UV sensor. 7. A customized type of sensor is used for sequentially installment of several generators. 8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system. 9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power. 10. It has the characteristics of proper functioning in different combustion chambers. 11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood. 12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions. 13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system. 14. Ease of installation of the gas train to the burner. 15. Standard protection of IP 54 mechanical parts. 16. IP 65 protection on demand. 17. Internal or external optional circulation of combustion gases in order to reduce NOx emissions. 18. It includes all the cables and power supply of the burner management system. 19. Includes impermeability control. 20. Compliance with the following directives: 89/336(2004/108)EEC 73/23/EEC 98/37/EEC EN 676 21. Sound insulated ventilation system |
260 | 950 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SC 8.1 GLM Gas /Light oil Modulation Monobloc Burner
SC 8.1 GLM Gas /Light oil Modulation Monobloc Burner
1. The following fuels can be used:
Natural gas PCI 6,99…11,39 kWh/Nm3. LPG, 25,89 kWh/Nm3 Light oil, viscosity 6 mm2 / s at 20 ° C, PCI11,86 kWh / kg 2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc. 3. The flame can be adjusted according to the combustion chamber. 4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation. 5. The 1/ 10 regulation of the electronic modulation power, is really advantageous compared to our rivals. 6. Flame monitoring is easy and reliable thanks to the UV sensor. 7. A customized type of sensor is used for sequentially installment of several generators. 8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system. 9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power. 10. It has the characteristics of proper functioning in different combustion chambers. 11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood. 12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions. 13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system. 14. Ease of installation of the gas train to the burner. 15. Standard protection of IP 54 mechanical parts. 16. IP 65 protection on demand. 17. Internal or external optional circulation of combustion gases in order to reduce NOx emissions. 18. It includes all the cables and power supply of the burner management system. 19. Includes impermeability control. 20. Compliance with the following directives: 89/336(2004/108)EEC 73/23/EEC 98/37/EEC EN 676 21. Sound insulated ventilation system |
330 | 1150 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SC 8.2 GLM Gas /Light oil Modulation Monobloc Burner
SC 8.2 GLM Gas /Light oil Modulation Monobloc Burner
1. The following fuels can be used:
Natural gas PCI 6,99…11,39 kWh/Nm3. LPG, 25,89 kWh/Nm3 Light oil, viscosity 6 mm2 / s at 20 ° C, PCI11,86 kWh / kg 2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc. 3. The flame can be adjusted according to the combustion chamber. 4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation. 5. The 1/ 10 regulation of the electronic modulation power, is really advantageous compared to our rivals. 6. Flame monitoring is easy and reliable thanks to the UV sensor. 7. A customized type of sensor is used for sequentially installment of several generators. 8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system. 9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power. 10. It has the characteristics of proper functioning in different combustion chambers. 11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood. 12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions. 13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system. 14. Ease of installation of the gas train to the burner. 15. Standard protection of IP 54 mechanical parts. 16. IP 65 protection on demand. 17. Internal or external optional circulation of combustion gases in order to reduce NOx emissions. 18. It includes all the cables and power supply of the burner management system. 19. Includes impermeability control. 20. Compliance with the following directives: 89/336(2004/108)EEC 73/23/EEC 98/37/EEC EN 676 21. Sound insulated ventilation system |
430 | 1600 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SC 8.3 GLM Gas /Light oil Modulation Monobloc Burner
SC 8.3 GLM Gas /Light oil Modulation Monobloc Burner
1. The following fuels can be used:
Natural gas PCI 6,99…11,39 kWh/Nm3. LPG, 25,89 kWh/Nm3 Light oil, viscosity 6 mm2 / s at 20 ° C, PCI11,86 kWh / kg 2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc. 3. The flame can be adjusted according to the combustion chamber. 4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation. 5. The 1/ 10 regulation of the electronic modulation power, is really advantageous compared to our rivals. 6. Flame monitoring is easy and reliable thanks to the UV sensor. 7. A customized type of sensor is used for sequentially installment of several generators. 8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system. 9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power. 10. It has the characteristics of proper functioning in different combustion chambers. 11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood. 12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions. 13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system. 14. Ease of installation of the gas train to the burner. 15. Standard protection of IP 54 mechanical parts. 16. IP 65 protection on demand. 17. Internal or external optional circulation of combustion gases in order to reduce NOx emissions. 18. It includes all the cables and power supply of the burner management system. 19. Includes impermeability control. 20. Compliance with the following directives: 89/336(2004/108)EEC 73/23/EEC 98/37/EEC EN 676 21. Sound insulated ventilation system |
580 | 2100 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SC 11.1 GLM Gas /Light oil Modulation Monobloc Burner
SC 11.1 GLM Gas /Light oil Modulation Monobloc Burner
1. The following fuels can be used:
Natural gas PCI 6,99…11,39 kWh/Nm3. LPG, 25,89 kWh/Nm3 Light oil, viscosity 6 mm2 / s at 20 ° C, PCI11,86 kWh / kg 2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc. 3. The flame can be adjusted according to the combustion chamber. 4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation. 5. The 1/ 10 regulation of the electronic modulation power, is really advantageous compared to our rivals. 6. Flame monitoring is easy and reliable thanks to the UV sensor. 7. A customized type of sensor is used for sequentially installment of several generators. 8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system. 9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power. 10. It has the characteristics of proper functioning in different combustion chambers. 11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood. 12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions. 13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system. 14. Ease of installation of the gas train to the burner. 15. Standard protection of IP 54 mechanical parts. 16. IP 65 protection on demand. 17. Internal or external optional circulation of combustion gases in order to reduce NOx emissions. 18. It includes all the cables and power supply of the burner management system. 19. Includes impermeability control. 20. Compliance with the following directives: 89/336(2004/108)EEC 73/23/EEC 98/37/EEC EN 676 21. Sound insulated ventilation system |
620 | 3000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SC 11.2 GLM Gas /Light oil Modulation Monobloc Burner
SC 11.2 GLM Gas /Light oil Modulation Monobloc Burner
1. The following fuels can be used:
Natural gas PCI 6,99…11,39 kWh/Nm3. LPG, 25,89 kWh/Nm3 Light oil, viscosity 6 mm2 / s at 20 ° C, PCI11,86 kWh / kg 2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc. 3. The flame can be adjusted according to the combustion chamber. 4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation. 5. The 1/ 10 regulation of the electronic modulation power, is really advantageous compared to our rivals. 6. Flame monitoring is easy and reliable thanks to the UV sensor. 7. A customized type of sensor is used for sequentially installment of several generators. 8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system. 9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power. 10. It has the characteristics of proper functioning in different combustion chambers. 11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood. 12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions. 13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system. 14. Ease of installation of the gas train to the burner. 15. Standard protection of IP 54 mechanical parts. 16. IP 65 protection on demand. 17. Internal or external optional circulation of combustion gases in order to reduce NOx emissions. 18. It includes all the cables and power supply of the burner management system. 19. Includes impermeability control. 20. Compliance with the following directives: 89/336(2004/108)EEC 73/23/EEC 98/37/EEC EN 676 21. Sound insulated ventilation system |
680 | 4000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SC 11.3 GLM Gas /Light oil Modulation Monobloc Burner
SC 11.3 GLM Gas /Light oil Modulation Monobloc Burner
1. The following fuels can be used:
Natural gas PCI 6,99…11,39 kWh/Nm3. LPG, 25,89 kWh/Nm3 Light oil, viscosity 6 mm2 / s at 20 ° C, PCI11,86 kWh / kg 2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc. 3. The flame can be adjusted according to the combustion chamber. 4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation. 5. The 1/ 10 regulation of the electronic modulation power, is really advantageous compared to our rivals. 6. Flame monitoring is easy and reliable thanks to the UV sensor. 7. A customized type of sensor is used for sequentially installment of several generators. 8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system. 9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power. 10. It has the characteristics of proper functioning in different combustion chambers. 11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood. 12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions. 13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system. 14. Ease of installation of the gas train to the burner. 15. Standard protection of IP 54 mechanical parts. 16. IP 65 protection on demand. 17. Internal or external optional circulation of combustion gases in order to reduce NOx emissions. 18. It includes all the cables and power supply of the burner management system. 19. Includes impermeability control. 20. Compliance with the following directives: 89/336(2004/108)EEC 73/23/EEC 98/37/EEC EN 676 21. Sound insulated ventilation system |
750 | 5000 |